Saiwang report SCLG05202600398 identifies Zhuxiangmu impact-protection board supplied by Hubei Kaijie. Production batch/date: 2026-04-21; issue date: 2026-05-29. Its three inspected items follow Q/HBKJ001-2026.

Test itemRecorded resultStated criterion
Surface staining / corrosionNo staining or corrosionNo staining or corrosion
Surface scratchingNo continuous scratch greater than 90%; pattern undamagedSame wording as the recorded result
Thickness swelling after water absorption7.8%≤10.5%

Thickness swelling is not a waterproof-assembly approval. These three tests do not establish impact energy or structural load capacity.

Emissions are not measured in one interchangeable unit.

CTI A2250285730104001C concerns an assembled wall-panel sample described as white plastic with a light-yellow film, issued 2025-05-15. Its TVOC and vinyl-chloride-monomer results are separate measurements.

Item / methodResultDetection limitReport limit
TVOC
HJ 571-2010 Annex A
N.D.0.05 mg/(m²·h) (72h)0.50 mg/(m²·h) (72h)
Vinyl chloride monomer
GB/T 4615-2013
N.D.0.1 mg/kg≤5 mg/kg

N.D. means below the method detection limit, not zero. The first result is an area-specific emission rate at the stated 72-hour condition; it is not room concentration in mg/m³. The second concerns content per mass. Neither replaces the separate SPC formaldehyde record below.

Results apply to the named specimens and stated test conditions. Request the applicable complete report for your product and market.

REQUEST THE APPLICABLE RECORD →

TECHNICAL / CONDITIONS MATTER

Similar headings. Different specimens.

Keep the water-based veneer, assembled wall panel and bamboo/wood-fibre records separate. A date, specimen and test arrangement are part of the result.

Water-based Zhuxiangmu veneer: three measured items

Saide report 认委-ST-CY-ZJ-25112031-01, dated 2025-12-09, concerns a 1 m × 8 mm × 1.5 m sample from Hubei Kaijie. It records three requested items under HJ 2540-2015; it is not a complete environmental certification for the product range.

ItemResultDetection limitReport criterion
Total phthalatesN.D.See compound-specific note below≤0.1%
Formaldehyde emissionN.D.0.005 mg/m³≤0.08 mg/m³
TVOC (72h)0.28 mg/(m²·h)0.01 mg/(m²·h)≤0.50 mg/(m²·h)

The phthalate detection limits are 0.001% for DBP / BBP / DEHP / DNOP and 0.005% for DINP / DIDP. The report lists GB/T 22048-2022 and HJ 571-2010 as test bases. Its 0.28 TVOC result is not substituted by the N.D. result from the different CTI assembled-wall-panel sample above.

Fire classification includes the test arrangement.

Two NOA reports record GB 8624-2012 B1(C-s2,d0) for their respective submitted samples. They are separate records, not one report replacing the other, and not an EN classification or a claim of non-combustibility.

RecordSpecimen / dateStated mounting condition
NFM-FRL250499-01Bamboo/wood fibre
2025-10-17
The single-burning-item note identifies a calcium-silicate substrate of about 900 kg/m³ and 9 mm thickness, a freestanding specimen and no specimen joint.
NFM2504-0089-01Assembled wall panel
2025-05-06
The single-burning-item note identifies the same stated substrate density/thickness, with the specimen mechanically screw-fixed above the substrate and with specimen joints.

900 kg/m³ and 9 mm describe the test substrate, NOT the KAIJIE panel. These laboratory arrangements are not a site-installation manual or a universal fastener specification. Neither report identifies a current sales SKU or panel size; confirm the actual product and assembly before applying its classification.

KEEP INSTALLATION DETAILS SEPARATE →

A substance screen is not a blanket market approval.

CTI A2250285730102001C, issued 2025-05-06, tested an assembled-wall-panel sample described as white plastic with light-yellow film. The report compares the submitted sample with the listed RoHS substance limits; this is not a website claim that every building product is RoHS-certified.

ItemResultDetection limitReport criterion
Pb / HgN.D.2 mg/kg1000 mg/kg
CdN.D.2 mg/kg100 mg/kg
Cr(VI)N.D.8 mg/kg1000 mg/kg
PBBs / PBDEsEach listed congener: N.D.25 mg/kg1000 mg/kg per group
DBP / BBP / DEHP / DIBPEach: N.D.50 mg/kg1000 mg/kg each

The report lists IEC 62321-series methods, with ICP-OES, UV-Vis and GC-MS used for different substances. N.D. is below the stated detection limit, not absence of all chemicals. No current SKU, universal safety claim or building approval is inferred.

01 / SPC WALL PANEL

Two records. One named specimen.

REACTION TO FIRE

CTI A2250712956101251

DATE
2026-04-10
SPECIMEN
SPC · 1220 × 2440 × 4 mm
METHOD & RESULT
GB 8624-2012 · B1(C)

The report records conformity with the stated B1(C) criteria. This Chinese-standard result is not an EN Euroclass or a fireproof-assembly claim.

SELECTED SUBSTANCES

CTI A2250712956101252

DATE
2026-04-10
LEAD
71.8 mg/kg · stated limit 1000 mg/kg
MERCURY
Not detected; recorded as conforming to the stated limit.
FORMALDEHYDE
GB/T 17657-2022 §4.61 · desiccator method, not detected

Not detected does not mean zero. Results from different methods are not interchangeable and do not establish an ENF classification.

02 / DECORATIVE PANELS

Tests follow the sample.

A2260207295101001C

2026-03-27 · GB/T 24137-2009 · JG/T 579-2021

Bamboo/wood-fibre specimens for decorative panels, grilles, ceilings and square profiles. Physical, surface and substance results apply to the tested specimens only.

A2260438434102

2026-04-22

Recorded categories include deformation, bonding, impact, staining, scratching and heavy metals. Results do not automatically apply to every cavity geometry, thickness, finish or installation.

Specify using the complete report, applicable product and project installation conditions.

Drawings first. Documents with a defined scope.

Request the relevant document

Tell us the product, market and intended application to request suitable drawings, installation details and technical reports.

PREPARE A DOCUMENT REQUEST →